Allister garage door repair may seem like a difficult task if you do not possess relevant experience of training. However, in fact it is easier than it seems. Even if you do not have an Allister garage door opener manual, you will find enough information in the Allister garage door troubleshooting chart below.

  • OWNER’S MANUAL INSTRUCTIONS MISC. ARD IIA: Allister: AUD SERIES: 190-106861M (Not Mfg. After 8/29/2010) 190-113269B (Solid State-Pre 2010 UL) AUJ SERIES.
  • How to Reconnect a Garage Door Opener After a Power Outage. It is surprising how many items you use each and every day that require electricity. What is more surprising is how you seem to forget.

Allister Model Ard Iia Manual Gearbox

2 My Allister Type IIA opener stopped working. When either the wall mount or remote was pushed, the light came on, the motor would hum, but garage did not open. I read in another opener manual that the problem might be that the trolley may be jammed into the stop bolts. Replacement for Models: 9921T 9931T 8822T 8832T. 8833T 9921MT 9931MT 9921TK. 9931TK 8832TK 9931TKB. Product Features. The Classic Quick Code Transmitter makes it possible to operate a single or group of remotely controlled devices such as a garage door opener, with a single transmitter.

SymptomProbable cause/solution
Operator does not activate (1)(2)(3)(4)(5)(6)(7)(15)
Operates with pushbutton but not with radio control(8)(9)(21)(22)(23)(7-Models 310/510)
Stops before reaching full Open or Closed position(3)(5)(6)(10)(11)(12)(13)(14)(23)
Reverses before reaching full Close position (6) (11)(14)
Reverses after door closes and contacts floor (16)(17)
Door opens and closes by itself (3)(12)(18)(23)
Light will not come on (19)(7)
Light will not turn off after operator runs (20) (7)
Transmitter has short range (8)(21)(22)(23)(7-Models 310/510)
Troubleshooting
1. Mechanical door lock enabled1. Disable or remove all door locks.
2. 120 Volt power not present at outlet2. Check wall switch, fuse, circuit breaker, etc.
3. Broken or shorted pushbutton, wiring or radio receiver(Model 710)3. Remove pushbutton wiring and radio receiver (Model 710) from the terminal strip on the back panel of the operator. Activate operator by momentarily connecting Terminals 1 & 2 with a test wire. If operator runs, reconnect items one at a time to find defective circuit. Replace.
4. Grid lock on motor control board4. Unplug operator, then reconnect.
5. Motor thermal overload protector opened5. Wait 30 minutes for motor to cool, try again.
6. Door jammed due to broken or incorrectly adjusted spring6. Ensure that door is in a closed position. Activate emergency release mechanism. If operator will run without door attached, contact your Allister garage door professional to repair door.
7. Defective motor control board7. Contact your local Allister garage door professional.
8. Weak battery in transmitter8. Replace battery.
9. Coding switches mismatched9. Reset switches to identical codes
10. Improper placement of limit cams on chain10. Correctly place placement of Limit Stops.
11. Door obstructed11. Remove all obstructions from door area.
12. Transmitter button stuck open12. Check transmitters to see if an indicator light is on at all times. If so, free button from casing.
13. Up sensitivity force improperly adjusted13. Adjust sensitivity.
14. Down sensitivity force improperly adjusted14. Adjust sensitivity.
15. Bottom of door frozen to ground15. Activate emergency release, clear away ice.
16. Ice and snow built up under door16. Clear away ice and snow to allow door to close.
17. Floor risen or sunk from weather change17. Reset down limit cam.
18. Someone in area with identical code18. Reset all radio controls with to new code.
19. Defective or burned out lamp bulb19. Replace with rough service bulb (60W max.)
20. Accidental push of light button on Deluxe Walt Station20. Push light button, light should go out. Activate operator, light should remain on for 4.5 minutes and then go out automatically.
21. Radio receiver not receiving signal21. Ensure that antenna wire from operator is pointing straight down toward the floor.
22. Transmitter location in car22. Ensure transmitter is clipped to sun visor. If it is clipped to dashboard or in ashtray, etc., range will be diminished.
23. Defective transmitter or receiver23. Contact your Allister garage door professional.

Products sold under the Allister brand are made by Allstar commercial operators. The company is one of the leading manufacturers of radio controls for the door and gate industries. The product range consists of residential and commercial radio controls. Models with three button open-close-stop functions are among the latest innovations.

Allister Iia Parts

Garage door opener not working easy fix

Model

If you have problems with a garage door opener manufactured by this brand, use the tables below. The list includes the most common symptoms, as well as troubleshooting advice.

Allstar LT 50 garage door opener troubleshooting

SYMPTOM:PROBABLE CAUSE/SOLUTION:
Opener does not activate (1) (2) (3) (4) (5) (6) (7) (15)
Operates with Push Button but not with radio control (8) (9) (21) (12) (23)
Stops before reaching full Open or Closed position (3) (5) (6) (10) (11) (13) (14) (23)
Reverses before reaching Full Close position (6) (11) (14)
Reverses after door closes and contacts floor (16)(17)
Door opens and closes by itself (3) (18) (23)
Light will not come on (19) (7)
Light will not turn off after Opener runs (20)(7)
Transmitter has short range (8)(21)(12)(23)
PROBABLE CAUSE:SOLUTION:
1. Mechanical door lock enabled1.Disable or remove all door locks.
2. 120 Volt power not present at terminal block2.Check wall switch, fuse box, circuit breaker, etc.
3. Broken or shorted Push Button, wiring or radio receiver3.Remove Push Button wiring and Radio Receiver from the terminal strip on the back panel of the operator. Activate Opener by momentarily connecting Terminals 1 & 2 with a test w ire. If Opener runs, reconnect items one at a time to find defective circuit Replace.
4. Grid lock on Motor Control Board4.Disconnect power to Opener, then reconnect
5. Motor Thermal Overload Protector opened5.Wait 30 minutes for Motor to cool, try again.
6. Door jammed due to broken or incorrectly adjusted spring6.Ensure that door is in a closed position. Activate Manual Release Mechanism If Opener will run without door attached, contact your AlLstar garage door professional to repair door
7. Defective Motor Control Board7.Contact your local AlLstar garage door professional
8. Weak Battery in Transmitter8.Replace Battery.
9. Radio Coding Switches mismatched9.Reset Switches to identical codes
10. Improper placement of Limit Stops on Chain10.Correctly place placement of Limit Stops.
11. Door obstructed11.Remove all obstructions from door area.
12. Defective Transmitter or Receiver12.Contact your Allstar garage door professional
13. Up sensitivity force improperly adjusted13.Adjust sensitivity.
14. Down sensitivity force improperly adjusted14.Adjust sensitivity.
15. Bottom of door frozen to ground15.Activate Manual Release, clear awavice.
16. Ice and snow built up under door16.Clear away ice and snow to allow door to close.
17. Floor risen or sunk from weather change17.Reset Down Limit Cam.
18. Someone in area with identical code18.Reset all radio controls to new code.
19. Defective or burned out lamp bulb19.Replace with rough service bulb (75W max.)
20. Radio Receiver not receiving signal20.Ensure that antenna wire from Opener is pointing straight down toward the floor.
21. Transmitter location in car21.Ensure Transmitter is clipped to sun visor. If it Is clipped to dashboard or in ashtray, etc., range will be diminished.
Model

Allstar SUPER BELT MVP-SB garage door opener troubleshooting

DIAGNOSTIC CONDITIONRED LEDGREEN LED
Normal OperationOFFOFF
Learn ModeONOFF
Memory FullON FOR 25 SEC, AUTO OFFOFF
Decode RF SignalSHORT FAST BLINKOFF
Shorted Push Button or Wire to ButtonOFFON
Photobeam ObstructionOFFFAST BLINK
Contact ReverseFAST BLINKOFF
Stuck RelaySLOW BLINKOFF
Stuck Open LimitOFFSLOW BLINK

Garage door opener not working easy fix